Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs.Setting parameters and FW update remotely, which makes PV plant O&M easier.
SUN-BK60SG01-EU-AM2
SUN-BK80SG01-EU-AM2
SUN-BK100SG01-EU-AM2
Model | SUN-BK60SG01-EU-AM2 | SUN-BK80SG01-EU-AM2 | SUN-BK100SG01-EU-AM2 |
Battery Input Data | |||
Battery Type | Lead-acid or Lithium-ion | ||
Battery Voltage Range (V) | 40-60 | ||
Max. Charging Current (A) | 25 | ||
Max. Discharging Current (A) | 25 | ||
Charging Strategy forLi-ion Battery | Self-adaption to BMS | ||
Number of Battery Input | 1 | ||
PV String Input Data | |||
Max. PV Access Power (W) | 1320 | 1760 | 2200 |
Max. PV Input Power (W)
|
960 | 1280 | 1600 |
Max. PV Input Voltage (V) | 60 | ||
Start-up Voltage (V) | 25 | ||
MPPT Voltage Range (V) | 20-55 | ||
Rated PV Input Voltage (V) | 42.5 | ||
Max. Operating PV Input Current (A) | 18+18 | ||
Max. Input Short-Circuit Current (A) | 27+27 | ||
No. of MPP Trackers/ No. of StringsperMPP Tracker |
2/1 | ||
AC Input/Output Data | |||
Rated AC Input/Output Active Power (W) | 600 | 800 | 1000 |
Max. AC Input/Output Apparent Power (VA) | 660 | 880 | 1100 |
Rated AC Input/Output Current (A) | 2.8/2.7 | 3.7/3.5 | 4.6/4.4 |
Max. AC Input/Output Current (A) | 3/2.9 | 4.0/3.9 | 5/4.8 |
Max. Continuous AC Passthrough (grid to load) (A) | 10 | ||
Peak Power (off-grid) (W) | 2 times of rated power, 10s | ||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||
Rated Input/Output Voltage/Range (V) | 220/230 0.85Un-1.1Un | ||
Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | ||
Grid Connection Form | L+N+PE | ||
Total Current Harmonic Distortion THDi | <3% (of nominal power) | ||
DC Injection Current | <0.5% In | ||
Efficiency | |||
Max. Efficiency | 96.5% | ||
Euro Efficiency | 96.0% | ||
MPPTEfficiency | >99% | ||
Equipment Protection | |||
Integrated | DC Reverse Polarity Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Insulation Impedance Detection, DC Component Monitoring, Ground Fault Current Monitoring
Anti-islanding Protection
|
||
Surge Protection Level | TYPE II(DC),TYPE II(AC) | ||
General Data | |||
Operating Temperature Range (℃) | -40 to +65℃, >45℃ Derating | ||
Permissible Ambient Humidity | 0-100% | ||
Permissible Altitude | 2000m | ||
Noise (dB) | <25 | ||
Ingress Protection(IP) Rating | IP 67 | ||
Inverter Topology | Isolated | ||
Over Voltage Category | OVC II(DC), OVC III(AC) | ||
Communication
|
Wi-Fi, Lora, Bluetooth
|
||
Cabinet Size (WxHxD mm) | 364.5×183×32.85 (Excluding Connectors and Brackets) | ||
Weight (kg) | 4.3 | ||
Type of Cooling | Natural Cooling | ||
Warranty | 10 Years/15 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
||
Grid Regulation | IEC 61727, IEC 62116,CEI 0-21, EN 50549,NRS 097, RD 140, UNE 217002, G98,VDE-AR-N 4105 |
||
Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
No. 26 South YongJiang Road,
Daqi, Beilun, NingBo, Zhejiang, China.
+86-574-8612-0560(sales) / +86-574-8622-8852(service)
+86-574-8622-8816
Copyright@ 2024.Ningbo Deye Inverter Technology Co.,Ltd. All rights reserved. Solar Inverter Manufacturer