Model |
SUN-M60G4-EU-Q0 |
SUN-M80G4-EU-Q0 |
SUN-M100G4-EU-Q0 |
PV String Input Data |
|
Max. PV Input Power(W) |
210-420(2 Pieces) |
210-560(2 Pieces) |
210-700(2 Pieces) |
Max. PV Input Voltage(V) |
60 |
Start-up Voltage(V) |
20 |
MPPT voltage range(V) |
25-55 |
Rated PV Input voltage(V) |
42.5 |
Max. Input Short-Circuit Current (A) |
19.5+19.5 |
Max. Operating PV Input Current(A) |
13+13 |
No. of MPP Trackers/No. of String per MPP Tracker |
2/1 |
AC Output Side
|
|
Rated AC Output Active Power(W) |
600 |
800 |
1000 |
Max.AC Output Apparent Power(VA) |
600 |
800 |
1000 |
Rated AC output current (A) |
2.8/2.7 |
3.7/3.5 |
4.6/4.4 |
Max.AC Output Current(A) |
2.8/2.7 |
3.7/3.5 |
4.6/4.4 |
Rated output voltage/range (V) |
220/230 0.85Un-1.1Un |
Grid Connection Form |
L/N/PE |
Rated Output Grid Frequency/range(Hz) |
50/45-55, 60/55-65 |
Max. unit per branch |
8 |
6 |
5 |
Power Factor Adjustment Range |
0.9 leading to 0.9lagging |
Total Current Harmonic Distortion THDi |
<3% |
DC Injection Current |
<0.5%ln |
Efficiency |
|
Max. Efficiency |
96.5% |
Euro Efficiency |
|
96.0% |
|
MPPT Efficiency |
>99% |
Equipment Protection |
|
DC Polarity Reverse Connection Protection |
YES |
AC Output Overcurrent Protection |
YES |
AC Output Overvoltage Protection |
YES |
AC Output Short Circuit Protection |
YES |
Thermal Protection |
YES |
DC Terminal Insulation Impedance Monitoring |
YES |
Power Network Monitoring |
YES |
Island protection monitoring |
YES |
Earth Fault Detection |
YES |
Overvoltage Load Drop Protection |
YES |
Interface |
|
Communication Interface |
WiFi |
General Data |
|
Operating Temperature Range (°C) |
-40 to +65℃, >45℃ Derating |
Permissible Ambient Humidity |
0~100% |
Permissible Altitude (m) |
2000m |
Noise (dB) |
≤ 25 |
Ingress Protection(IP) Rating |
IP 67 |
Inverter Topology |
Isolated |
Over Voltage Category |
OVC II(DC),OVC III(AC) |
Cabinet Size(W*H*D)[mm] |
280.5*190*40(Excluding connectors and brackets) |
Weight [kg] |
3 |
Warranty [year] |
15 Years |
Type Of Cooling |
natural cooling |
Grid Regulation |
IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002, ,G98,VDE-AR-N 4105 |
Safety EMC/Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |