Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs.Setting parameters and FW update remotely, which makes PV plant O&M easier.
SUN-8K-SG01HP2-US-SM2
SUN-10K-SG01HP2-US-SM2
SUN-12K-SG01HP2-US-SM2
SUN-15K-SG01HP2-US-SM2
Model | SUN-8K-SG01HP2 -US-AM2 |
SUN-10K-SG01HP2 -US-AM2 |
SUN-12K-SG01HP2 -US-AM2 |
SUN-15K-SG01HP2 -US-AM2 |
Battery Input Data | ||||
Battery Type | Lithium-ion | |||
Battery Voltage Range (V) | 160-500 | |||
Max. Charging Current (A) | 50 | |||
Max. Discharging Current (A) | 50 | |||
Charging Strategy forLi-ion Battery | Self-adaption to BMS | |||
Number of Battery Input | 1 | |||
PV String Input Data | ||||
Max. PV Access Power (W)
|
16000 | 20000 | 24000 | 30000 |
Max. PV Input Power (W) | 12000 | 15000 | 18000 | 22500 |
Max. PV Input Voltage (V) | 550 | |||
Start-upVoltage (V) | 180 | |||
MPPT Voltage Range (V) | 150-500 | |||
Rated PV Input Voltage (V) | 380 | |||
Max. Operating PV Input Current (A) | 26+26 | |||
Max. Input Short-Circuit Current (A) | 39+39 | |||
No. of MPP Trackers/No. of Strings MPP Tracker | 2/2+2 | |||
AC Input/Output Data | ||||
Rated AC Input/Output Active Power (W) | 8000 | 10000 | 12000 | 15000 |
Max. AC Input/Output Apparent Power (VA) | 8000 | 10000 | 12000 | 15000 |
Rated AC Input/Output Current (A) | 33.4 | 41.7 | 50 | 62.5 |
Max. AC Input/Output Current (A) | 33.4 | 41.7 | 50 | 62.5 |
Max. Continuous AC Passthrough (grid to load) (A) | 150 | |||
Peak Power (off-grid) (W) | 1.5 times of rated power, 10s | |||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |||
Rated Input/Output Voltage/Range (V) | 120/240, 208 0.85Un-1.1Un | |||
Rated Input/Output Grid Frequency/Range(Hz) | 60/55-65 | |||
Grid Connection Form | 2L+N+PE | |||
Total Current Harmonic Distortion THDi | <3% (of nominal power) | |||
DC Injection Current | <0.5% In | |||
Efficiency | ||||
Max. Efficiency | 97.6% | |||
Euro Efficiency | 97.0% | |||
MPPTEfficiency | >99% | |||
Equipment Protection | ||||
Integrated |
DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection
|
|||
Surge Protection Level | TYPE II(DC),TYPE II(AC) | |||
Interface | ||||
Communication Interface | RS485/RS232/CAN | |||
Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN(optional) | |||
General Data | ||||
Operating Temperature Range (℃) | -40 to +60℃, >45℃ Derating | |||
Permissible Ambient Humidity | 0-100% | |||
Permissible Altitude | 2000m | |||
Noise (dB) | ≤55 | |||
Ingress Protection(IP) Rating | TYPE3R | |||
Inverter Topology | Non-Isolated | |||
Over Voltage Category | OVC II(DC), OVC III(AC) | |||
Cabinet Size (WxHxD mm) | 436×680×277.5 (Excluding Connectors and Brackets) | |||
Weight (kg) | 34.8 | |||
Type of Cooling | Intelligent Air Cooling | |||
Warranty | 5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
|||
Grid Regulation | IEEE 1547.1,SRD V2.0 | |||
Safety / EMC Standard | FCC, UL 1741 |
No. 26 South YongJiang Road,
Daqi, Beilun, NingBo, Zhejiang, China.
+86-574-8612-0560(sales) / +86-574-8622-8852(service)
+86-574-8622-8816